Specifications Model:DASV10-20
Two-year warranty
DASV10-20Poppet, 2-Way, Normally Closed
DESCRIPTION
A solenoid-operated, 2-way, normally closed, poppet-type, screw- in hydraulic cartridge valve, designed to function as a load holding or blocking valve in applications requiring low internal leakage.
OPERATION
When de-energized,DASV10-20 acts as a check valve, allowing flow to pass from 1 to 2 , while blocking flow in the reverse direction. With the sensor option, the neutral sensor will signal ON
or HIGH.When energized, the poppet lifts to open the 2 to 1 flow path. In this mode,flow from 1 to 2 is severely restricted. (If this path is required, see model DASV10-22,With the sensor option, the neutral sensor will signal LOW or OFF.Operation of Manual Override Option: To override, push button in, twist counterclockwise 180 ° and release. In this position, the valve will remain open.To return to normal operation, push button in, twist clockwise 180° and release. Override will be detented in this position.
FEATURES
● Continuous-duty rated solenoid.
● Hardened seat for long life and low leakage.
● Optional coil voltages and terminations.
● Efficient wet-armature construction.
● Cartridges are voltage interchangeable.
● Manual OverrideOptions.
● Optional waterproof E-Coils rated up to IP69K.
● Unitized, molded coil design.
● Industry common cavity.
RATINGS
Operating Pressure:207 bar (3000 psi)
Proof Pressure:350 bar (5075 psi)
Flow:See Performance Chart
Internal Leakage: 0.15 cc/minute (3 drops/minute) max. at 207 bar (3000 psi)
Temperature:-40℃ to 120℃,with Buna N seals
Coil Duty Rating:Continuous from 85% to 115% of nominal voltage
Response Time:First indication of change of state with 100% voltage supplied at 80% of nominal flow rating: Energized: 40
msec.; De-energized: 32 msec.
Response Time with Sensor: 53 ms pull-in, 110 ms drop-out
Initial Coil Current Draw at 20℃ :
Standard Coil:121.67 amps at 12 VDC;0.18 amps at 115 VAC (full wave rectified)
E-Coil:1.7 amps at 12 VDC; 0.85 amps at 24 VDC
Minimum Pull-in Voltage:85% of nominal at 207 bar (3000 psi)
Fluids:Mineral-based or synthetics with lubricating properties at viscosities of 7.4 to 420 cSt (50 to 2000 ssu)
Cavity: